With the development of science, technology and technological level in the world, the requirements for plugs and sockets products are getting higher and higher. Different from low price and low quality products flooding the market in the past, the plugs and sockets on sale are required to be certified: China Compulsory Certification in the market now or for sold in Europe and America, they must meet the requirements of IEC60884-1 (or other corresponding international standards), which greatly improves the requirements for manufacturers in terms of quality control.
In fact, 3C authentication is actually a combination of CCEE, CCIB, EMC and the test requirements of 3C authentication for plugs and sockets are mainly concentrated in the GB standards. For the products circulating in the international market, they must meet the general requirements of IEC-60884-1.
The main test items for these series standards are the following:
Part 1 General requirements
This section defines and sorts the types of plugs and sockets. For example, the working voltage is usually 50V~440V, the working current of the plugs and sockets with screw type terminals is limited to 32A, and the fixed socket-outlets without screw terminals is limited to 16A. For the specifications of rated current and voltage value, please refer to the requirements in table IEC60884-1 6.1. At the same time, it requires the requirements of the environment temperature for carrying the routine tests: If there are no special requirements, the environment temperature should be in 15°~35°or 20 °±5° (LISUN recommends GDJS series high and low temperature humidity chamber to ensure the test temperature).
Part 2 Dimension check
This part of the test mainly includes: plug and draw test (insert the plug into the socket 10 times continuously); use the gauge to measure the center distance; fitness check of the socket and plug. For specific requirements, please refer to the requirements in table IEC60884-1 9.1. (LISUN recommends the use of professional micrometers, vernier calipers, and LG series plug and socket gauges for inspection.)
Part 3 Protection against electric shock
In IEC60884-1, the requirements of protection against electrical shock of plugs and sockets are as follows:
Except the judgment via the naked eye, LISUN recommends to use professional electric shock / shock testing equipment, such as test finger / straight finger with propulsive force / electrical indicator, probe (TZ-1), test ball line bar (QXB-1) to carry the test.
Part 4 Ground test
This part of the test is a critical part of the electrical safety performance in the plug and socket test, and the following requirements have been made in the IEC60884-1:
For these tests, LISUN recommends TOS3200 contact resistance meter and other AC power supplies (LSP-Series).
Part 5 Terminals test
In the twelfth part of IEC60884-1, the following requirements are made for this part of the experiment:
At the same time, there are strict requirements in the standards for wire test (LISUN recommends DSS-1 conductor storage test device)
Part 6 Socket plug structure detection
In the thirteenth part of IEC60884-1, the following requirements are made for this part of the experiment:
Part 7 Resistance to aging test
The basic requirements for resistance to aging are as follows:
Part 8 Insulation resistance and electrical strength
Part 9 Normal operation/Temperature rise/Force necessary to withdraw the plugs
If others samples rate is 15 times/min, please refer to IEC60884-1 table 20 to carry the operations. (LISUN recommends DFX series load cabinet and CZKS series plug socket switch life tester for test)
Part 10 Others tests
In addition to the above test items, because there are many fine parts in the plug socket devices, IEC standards also provides corresponding testing requirements for them, such as:
With the higher and higher requirements for plugs and sockets products, the products will not be competitive in the future without certification and detection. The above tests only describe parts of the requirements of IEC60884-1, other requirements including size, color and structure, please refer to the corresponding test standards. There is no doubt that all manufacturers are faced with the problem of quality inspection. After years of research and development, LISUN has a full range of product lines, can provide customers with a full set of complete testing equipment. Customers can refer to the following table to choose:
Item | Product Name | Model Number | Technical Specs Introduction: | IEC60884 Clause |
1 | Vernier caliper/micrometer/Force Gauge | / | Can measure internal and external dimensions, depth dimensions and steps. Reading resolution: 0.02mm;Indication error: 0.02mm/Maximum range: 500N digital display |
IEC60884-1-9 |
2 | Plug socket gauge | / | Single phase/19units/set(Without ISO17025 calibration) | IEC60884-1-9 |
3 | Plug socket gauge | / | Three phases/15units/set(Without ISO17025 calibration) | IEC60884-1-9 |
/ | Three phases/24units/set(Without ISO17025 calibration) | IEC60884-1-9 | ||
4 | Anti-shock protection test device | / | Test finger, test thrust directed, electrical indicator | IEC60884-1-10 |
5 | Test probe | / | Section: 3mm * 1mm (flat) / Ф1mm (round) Pressure: 20N, 1N | IEC60884-1-10-5 |
6 | Compressure test device | / | 150 N pressure and steel plate. Working with oven together | IEC60884-1-10-1 |
7 | AC variable frequency power supply | LSP-5KVAS | Single phase: 5KVA | IEC60884-1-11-5 |
8 | Contact resistance meter | 30μA-30mA(rms) | IEC60884-1-11-5 | |
9 | Torque tools | / | Total 4 units/set | IEC60884-1-12-2 |
10 | Conductor damage test device | / | Single station or 2 station optional. Test rate: 10 ± 2r / min (GB16915.1: 12 ± 1r / min) Rotational radius: 37.5mm Test distance: 250 ~ 500mm(Adjustable) |
IEC60884-1-12-2 |
11 | Screwless terminal bending test device | / | Force direction: towards each phase of 30 °± 5 ° in any one direction Bending force: 0.25N, 0.5N, 1.0N Bend angle: 0-360 |
IEC60884-1-12 |
12 | Transverse stress test device | / | 12mm semi-circular probe, slowly applied 89N | UL1993/IEC60884-1-13.14 |
13 | Heating Chamber | / | Room temperature +10° ~ 200° | IEC60884-1-13.23/24 |
14 | High-low temperature & Humidity Chamber | GDJS-225B | —40 ~ 150 degrees / 30 ~ 98% RH, Touch screen control, the volume of 250L | IEC60884-1-13 |
15 | Non-solid bolt test device | / | Single station, Weight: 100 ± 1% N, Mandrel diameter: 4.8mm |
IEC60884-1-14.2 |
16 | Plug temperature rise test system | / | Contains YOKOGAWA temperature recorder 80A resistive load | IEC60884-1-14.23.1 |
17 | Temperature rise test box/Mounted board | Pine trough + box + plaster, pine board etc. | / | |
18 | Socket torque test device | / | Working with 10A, 16A three-pin socket and 10A dual-pin socket | IEC60884-1-14.23.2 |
19 | Water proof test wall | / | / | IEC60884-1-16.2.1 |
20 | Metal rods | / | 19 pcs / set, length 200mm | IEC60884-1-17.1.1 |
21 | Test ball bar | Meet IPX1 ~ 4X level requirements 1. Test ball: S ¢ 50mm 2. Test rod: ¢ 2.5mm / S ¢ 35mm / L = 100mm 3. Test line: ¢ 1mm / S ¢ 35mm / L = 100mm |
IEC60884-1-16.2 | |
22 | Dustproof Testing Machine | SC-800 | omplies with IP5X / 6X rating requirements Studio size: 800 × 800 × 800mm Temperature range: 15 ~ 35 ℃ (adjustable) Vacuum pump, PLC touch screen control |
IEC60884-1-16.2 |
23 | Water proof Tesing device | JL-12/JL-34/JL-56 | According to the IEC60529 | IEC60884-1-16.2 |
24 | Insulation Resistance Tester | 0.01MΩ-5000MΩ | IEC60884-1-17.1 | |
25 | Withstand testing device | Test voltage: AC / DC 5KV Breakdown current: 100mA (AC) / 10mA (DC) |
IEC60884-1-17.2 | |
26 | Temperature rise & clamping test device | / | / | IEC60884-1-19 |
28 | Breaking capacity and life test system | / | 3 station touch screen control. including a load cabinet 35A. | IEC60884-1-20 |
29 | Multi-function pull-out test device | / | Can measure maximum pull-out force, the minimum pull-out force and lateral stress. For 10A, 16A socket | IEC60884-1-22.1 |
30 | Soft cable reliability test device | Single station, weight: 50N \ 60N \ 80N \ 100N each one, electric control | IEC60884-1-23.2 | |
31 | Bending test device | Intelligent control with load, 2 station | IEC60884-1-23.4 | |
32 | IK Level Tester | IK07-10 | Pendulum shaft length: 1000mm Shock height: 100mm, 150mm, 200mm, 250mm Impact element quality: 150g | IEC60884-1-24.1 |
33 | Drum drop test device | / | Speed: 5rpm (adjustable), counter: 0 ~ 9999 can be preset | IEC60884-1-24.2 |
34 | Surface socket test plate | / | / | IEC60884-1-24.3 |
35 | Low temperature impact test device | DWC-1 | Single station, impact weight: 1000g, stainless steel structure | IEC60884-1-24.4 |
36 | Metal rods | / | / | IEC60884-1-24.6 |
37 | Plug plug insulation sleeve wear test device | / | / | IEC60884-1-24.7 |
38 | Anti – monopole insertion test device | / | 40N/75N | IEC60884-1-24.8 |
39 | Multi – position mobile outlet mechanical strength test device | / | According to the IEC60884 | IEC60884-1-24.9 |
40 | Plug fastness test device | / | / | IEC60884-1-24.1 |
41 | Cylindrical steel bar | / | Diameter 3mm, the head radius of 1.5mm ball, ± 0.1mm; can be pulled Rally | IEC60884-1-24.11~13 |
42 | Cover test equipment and gauges | / | / | IEC60884-1-24.14~18 |
43 | Ball pressure test device | / | R = 2.5mm, pressure: 20N, 304 stainless steel With thermocouple hole (optional temperature display system | IEC60884-1-25 |
44 | Hot compression test device | / | 20N, R = 25mm, stainless steel (optional temperature display device) | IEC60884-1-25.4 |
45 | Creepage distance | / | 23 models, stainless steel | IEC60884-1-27 |
46 | Glow-wire Test Apparatus | ZRS-3H | According to the IEC60695-2-1 | IEC60884-1-28.1.1 |
47 | Plug insulation non – normal thermal test device for | / | IEC60884-1-28.1.2 | |
48 | Tracking Test Chamber | TTC-1 | According to the IEC60112 | IEC60884-1-28.2 |
49 | High temperature pressure test device | / | Blade thickness: 0.7 ± 0.01 mm, load: 2.5N weight | IEC60884-1-30.1 |
50 | Low temperature impact test device | / | Impact height 10 ~ 200mm adjustable, the sample length: 5D ~ 150D Material: 304 stainless steel Single-station or three-station optional, low-temperature box reprovision |
IEC60884-1-24.4 |
51 | Plug clamping test device | / | / | / |
52 | Flexible cable torsion test device | / | Single station; Weight: 50N \ 60N \ 80N \ 100N each one; Electric control |
/ |
53 | Insert | / | Can be even push Rally. Copper / copper alloy (≦ 25mm ± 0.1mm)> 25mm ± 0.5% | IEC60884 |
54 | Spring Impact Hammer/IK Level Tester | IK01-06 | 0.2J/0.35J/0.5J/1J, ±0.05J | IEC60884 |
55 | Plug Socket Switch Life Tester | CZKS-3 | 2 ~ 3 station, Full servo + precision screw PLC control, which can do both rotation and linear motion switch With -40 ~ 150 degrees high and low temperature box and hollow inductive load system, do more than 40 times the impact of current testing(Customsize) | IEC60884 |
Contact us if you need more info or quotations: Sales@Lisungroup.com