FOREWORD
This Indian Standard IS 15885 (Part 2/Sec 13 ) was adopted by the Bureau of Indian Standards, after the draft finalized by the Electric Lamps and Their Auxiliaries Sectional Committee had been approved by the Electrotechnical Division Council.
This standard IS 15885 (Part 2/Sec 13): 2012 specifies the general and safety requirements for d.c. or a.c. supplied electronic controlgear for LED modules for supply voltages up to and including 1 000V d.c. and a.c. supplies up to and including 1000V at 50 Hz.
The performance requirements have been covered in IS 16104: 2012‘d.c. or a.c. supplied electronic controlgear for LED modules – Preference requirements.
This standard IS 15885 (Part 2/Sec 13): 2012 , along with the other parts make up IS 15885 series on safety of lamp controlgear. In this standard while referring to any of the clauses of IS15885 (Part 1): 2011‘Safety of lamp controlgear: Part 1 General requirements’ specifies the extent to which such a clause is applicable and the order in which the tests are to be performed; they also include additional requirements as necessary’. All parts which make up IS 15885 (Part 2) are self-contained and therefore do not include references to each other.
Where the requirements of any of the clauses of IS 15885 (Part1) are referred to in this standard by the phrase “The requirements of Clause‘…’ of IS 15885 (Part 1) apply”, this phrase is interpreted as meaning that all requirements of the clause in question of Part 1 shall apply, except any, which are clearly inapplicable to the specific type of lamp control gear covered by this particular standard.
This standard IS 15885 (Part 2/Sec 13): 2012 is based onIEC61347-2-13, Ed 1 2006-05‘Lamp controlgear-Part 2-13: Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules’and IEC 34C/901A/DC‘d.c.or a.c. supplied electronic control gear for LED modules’issued by the International Electrotechnical Commission (IEC).
For the purpose of deciding whether a particular requirement of this standard is complied with, the final value, observed or calculated expressing the result of a test, shall be rounded off in accordance with IS 2: 1960‘Rules for rounding off numerical values (revised)’. The number of significant places retained in the rounded off value should be the same as that of the specified value in this standard.
LISUN supplies the fully test solutions for the following IS 15885 (Part 2/Sec 13): 2012, please see the below excel table:
IS 15885 (Part 2/Sec 13): 2012 Safety Of Lamp Controlgear Part 1 Particular Requirements-Section 13 d.c. or a.c. Supplied Electronic Controlgear for LED Modules | LISUN Model |
Clause 1 AC Supply | LSP-500VARC |
Clause 13 Thermal Endurance Test | GW-500 |
Clause 19 Resistance To Heat, Fire And Tracking |
GW-500 |
ZY-3 | |
TTC-1 | |
Clause 20 Resistance To Corrosion | YWX/Q-010 |
Clause 21.1 Moisture resistance | GDJS-015B |