This document is applicable to filament lamps, discharge lamps, LED light sources and LED packages to be used in road vehicles, i.e. in headlamps, fog-lamps, signalling lamps and interior lighting. It is especially applicable to those lamps and light sources which are listed in IEC 60809.
It specifies requirements and test methods for the measurement of performance charac-teristics such as lamp life, luminous flux maintenance, torsion strength, glass bulb strength and resistance to vibration and shock. Moreover, information on temperature limits, maximum lamp outlines and maximum tolerable voltage surges is given as guidance for lighting and electrical equipment design.
For some of the requirements given in this document, reference is made to data given in tables. For lamps not listed in such tables, the relevant data are supplied by the lamp manufacturer or responsible vendor.
The performance requirements are additional to the basic requirements specified in IEC 60809. They are, however, not intended to be used by authorities for legal type-approval purposes.
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments)applies.
IEC 60050-845, International Electrotechnical Vocabulary – Part 845: Lighting
IEC 60061-1, Lamp caps and holders together with gauges for the control of interchangeability and safety -Part 1: Lamp caps
IEC 60068-2-14, Environmental testing – Part 2-14: Tests – Test N: Change of temperature
IEC 60068-2-43, Environmental testing – Part 2-43: Tests – Test Kd: Hydrogen sulphide test for contacts and connections
IEC 60068-2-58, Environmental testing – Part 2-58: Tests – Test Td: Test methods for solderability, resistance to dissolution of metallization and to soldering heat of surface mounting devices(SMD)
IEC 60810:2017 Clause and Subject | LISUN Model |
Clause 3.1-3.6 and 5 Luminous Flux Maintenance | LEDLM-84PL |
Clause 4.2 Torsion Strength | CH338 |
Clause 4.4 Lamps Life Test | SY2036 |
Clause 4.6 Resistance to Vibration | LVD-100KG |
Clause 7 Test Conditions for LED Light Sources | LPCE-2 |
Clause 7.6 Powered Thermal Cycling Test | GDJS-015B |
Clause 8.6.19 DEW Test | |
Clause 7.12-7.13 Transient Voltage Test | SUG335 |
Clause 7.14 Electrostatic Discharge Test (ESD) | ESD61000-2 |
Clause 8.6.3 High Temperature Operating Life(HTOL) Test | GW-500 |
Clause 8.6.7-8.6.8 Electrostatic discharge,(ESD-HBM)&(ESD-MM) Test | ESD-883D |
Clause 8.6.16 Thermal Shock (TMSK) Test | HLST-500D |
Clause 8.6.20 Gas Corrosion Test | SQ-010 |
Your email address will not be published. Required fields are marked *
[wpforms id="9600"]