+8618117273997weixin
English
中文简体 中文简体 en English ru Русский es Español pt Português tr Türkçe ar العربية de Deutsch pl Polski it Italiano fr Français ko 한국어 th ไทย vi Tiếng Việt ja 日本語

Photovoltaic Impulse Voltage Generator

Product No: SUG1250-30KV

Leave a Message

[wpforms id="9600"]
  • Description
  • The photovoltaic impulse voltage generator is designed as per 7.5.1 Impulse voltage test (type test) in IEC 62109-1 Safety of power converters for use in photovoltaic power systems –Part 1: General requirements and photovoltaic inverter impulse voltage test specified in GB/T 37408, which is capable of generating 1.2/50 μs impulse test waveform ranging from 0.5 kV to 25 kV. The source impedance covers two types: less than 2 ohm and 500 ohm, which can satisfy the clearances and solid insulation test requirement.

    Standard:
    IEC 60060-1 ” High-voltage test techniques – Part 1 General definitions and test requirements”
    IEC 62109-1 “Safety of Power Converter for use in Photovoltaic Power SystemsPart 1: General requirements”

    System configuration and main technical specification:
    SUG1250-30KV impulse surge test system includes: 1.2/50μs impulse test generator and voltage waveform attenuator
    • According to IEC/EN 61730-1, IEC/EN 61730-2 and IEC 60060-1 standards
    • Voltage wave: 1.2/50μs
    • Output voltage: 2~30kV
    • Test capacitance: 2~150nF
    • Output polarity: Positive or Negative
    • Surge repetition: 20~9999 times
    • Surge interval: 30~999 seconds

    Circuit principle:

    Circuit principle

    Output waveform definition
    voltage wave
    Front time: T1=1.67T=1.2μs±30%
    Half time: T2=50μs±20%

    Output waveform

    Normal working conditions:
    • Ambient temperature: 10~35℃
    • Relative temperature: 10%~65%
    • Atmospheric pressure: 86~106KPa
    • Rated working voltage: 220V±10% & 50/60Hz

    Accessory:
    • AC 220V single phase power cable (1pc)
    • Standard test parts (1set)
    • User manual

    Touchscreen program interface:

    Touchscreen program interface:

    The picture above shows the initial interface. The first line is the function selection menu. Click directly to enter the corresponding function interface.

    The current interface is the impulse voltage test function interface (“Impulse test” is white on a red background).

    The white box in the upper left corner of the interface shows that the generator is a 1.2/50 generator. When you click on the blues boxes in the middle, the editing number table will appear, and you can edit the corresponding parameters for testing.

    Tags: