Purpose of Rapid temperature change test chamber

The Rapid temperature change test chamber is applicable to the detection of various performance indicators of aerospace products, information electronics, instruments and meters, materials, electricians, electronic products and various electronic components under the condition of rapid temperature change.

Rapid temperature chamge test chamber: It is mainly used to conduct environmental simulation test on the physical and other relevant characteristics of products under low and high temperature conditions according to the requirements of national standards or user’s own requirements, and judge whether the performance of products can meet the requirements through the test results, so as to provide for product design, improvement, identification and delivery inspection.

Because the Rapid temperature chamge test chamber is mainly composed of a chamber, a cooling system, a heating system, an air circulation system and a control system, the shell of the chamber is made of “cold-rolled steel sheet and electric spray” (users can choose high-quality stainless steel sheet); The inner liner is made of high-quality stainless steel plate; A “large area observation window” is set in the middle of the box door and equipped with an observation lamp, so that users can clearly see the condition of the sample and the overall appearance is beautiful and generous. The thermal insulation layer of this test box is “rigid polyurethane foam plus a small amount of ultra-fine glass wool”, so it should have high strength and good thermal insulation performance.

Rapid temperature change test chamber: the main temperature controller is (intelligent digital temperature and humidity controller), and the operation method of humanized design is easy to learn and use, because the operation of instruments of different functional grades should be compatible with each other; For the input, the digital correction system is adopted, as well as the built-in common thermocouple and thermal resistance nonlinear correction table, so that the measurement is accurate and stable; It also has AI artificial intelligence adjustment function, 0.2 level accuracy and multiple alarm modes; The refrigeration system adopts totally enclosed imported compressor unit, with mechanical single-stage refrigeration or overlapping low-temperature circuit system, and can fully automatic control and safety protection coordination system; The machine is heated by stainless steel finned heating tubes.

How to deal with abnormal startup of Rapid temperature change test chamber:
1、 If the exhaust compression of the rapid temperature change test chamber is too high, first find out the possible causes:
1) Insufficient cooling water volume of water-cooled condenser or insufficient cooling air volume of air-cooled condenser;
2) The scale on the surface of the condenser tube cluster is too thick or the oil stain is too thick, which should cause heat dissipation difficulties;
3) There is air in the refrigeration system;
4) Excessive refrigerant filling;
5) The valve in the exhaust pipe fails, resulting in high pressure;

Corresponding elimination method:
1) Check whether the non-valve is fully open, increase the water supply or check whether the motor voltage, speed and drive belt are too loose;
2) Clean the scale and oil to make the surface of condenser tube clean;
3) Discharge air;
4) Discharge excess refrigerant;
5) Check and correct the valve;

2、 When there is abnormal sound in the cylinder of the test chamber, the possible causes are:
1) The clearance in the cylinder is too small;
2) The clearance between piston pin and connecting rod bushing is too large;
3) The valve plate is broken;
4) The oil knocking noise caused by oil splashing on the crankshaft crank or connecting rod big end.

Corresponding exclusion method:
1) Adjust the thickened cylinder gasket;
2) Replace the piston pin or bushing;
3) Stop the machine immediately to replace the valve plate;
4) It is not necessary to stop the machine for a short time. If it lasts for several minutes, it is necessary to stop the machine for inspection;

Features of Rapid temperature change test chamber:
A. Intelligent control system: the large compressor is automatically started to cool down in case of rapid cooling, and the high temperature and temperature rise process is controlled linearly by the balance temperature of the small compressor to save energy;

B. Energy-saving, carbon-reducing and power-saving design, rapid temperature change test chamber stability and energy-saving efficiency, saving more than 30% year on year;

C. The controller adopts the new fuzzy algorithm technology to control and automatically adjust the cold coal flow, effectively take away the heating load of the tested object to achieve the control effect;

D. The Rapid temperature change test chamber can set different stress screening temperature change rates of 5 ℃/min, 10 ℃/min, 15 ℃/min, 20 ℃/min;

E. It can perform various tests such as rapid temperature change (stress screening), condensation test, high temperature and high humidity, temperature and humidity cycle, etc;

F. Meet the requirements of stress screening test for electronic equipment products;

Daily maintenance of Rapid temperature change test chamber:
1. The Rapid temperature change test chamber shall be placed in a relatively benign temperature environment, with the ambient temperature and humidity of 5 ℃~+30 ℃ ≤ 85% R.H. For laboratories without this condition, appropriate air conditioning or cooling tower shall be equipped to ensure the service life of the compressor and the overall test effect of the test chamber.

2. Water circuit and humidifier cleaning: if the water circuit is not smooth and the humidifier is prone to scale, the humidifier will burn dry and may damage the humidifier, so the water circuit and humidifier must be cleaned regularly.

3. Adhere to professional management by specially-assigned personnel. Units with conditions shall send personnel to the supplier for training and learning from time to time to obtain more professional maintenance and repair experience and ability. Regular cleaning of the test chamber shall ensure good ventilation and heat exchange performance; It regularly cleans the inside of the condenser to obtain continuous heat exchange performance.

4. Cleaning and balancing of circulating fan blades and condenser fans: similar to cleaning evaporator, due to the different working environment of the rapid temperature change test chamber, many small particles such as dust will condense on the circulating fan blades and condenser fans, which should be cleaned regularly.

The rapid temperature change & humidity heat  test chamber is a temperature and humidity test device, applied for aerospace products, information electronic instruments, electrical, electronic products, and various electronic components to test various products under the condition of rapid temperature change performance.

KWB-054D Rapid temperature change & humidity heat test chamber

Lisun Instruments Limited was found by LISUN GROUP in 2003. LISUN quality system has been strictly certified by ISO9001:2015. As a CIE Membership, LISUN products are designed based on CIE, IEC and other international or national standards. All products passed CE certificate and authenticated by the third party lab.

Our main products are GoniophotometerIntegrating SphereSpectroradiometerSurge GeneratorESD Simulator GunsEMI ReceiverEMC Test EquipmentElectrical Safety TesterEnvironmental ChamberTemperature ChamberClimate ChamberThermal ChamberSalt Spray TestDust Test ChamberWaterproof TestRoHS Test (EDXRF)Glow Wire Test and Needle Flame Test.

Please feel free to contact us if you need any support.
Tech Dep: Service@Lisungroup.com, Cell/WhatsApp:+8615317907381
Sales Dep: Sales@Lisungroup.com, Cell/WhatsApp:+8618117273997

Tags:

Leave a Message

Your email address will not be published. Required fields are marked *

[wpforms id="9600"]