Apparatus for Mechanical Strength Test on Resilient Covers with BS 1363 Figure 2
12 May, 2024 281 Author: Cherry Shen

Apparatus for Mechanical Strength Test on Resilient Covers with BS 1363 Figure 2

10. Accessibility of live parts 10.1 Live parts of plugs shall not be accessible when the plugs are wired as in normal use and in full engagement in a corresponding socket-outlet. Removal of detachable fuse carriers shall not result in live parts becoming accessible when the plug is in full engagement with the socket-outlet or the socket-outlet portion of an adaptor. 10.1.1 Conformity shall be che...

Read More
Test Probe 14 of IEC 61032 Figure 10 (Test Bar)
11 May, 2024 333 Author: Cherry Shen

Test Probe 14 of IEC 61032 Figure 10 (Test Bar)

1 General 1.1 Scope and object This International Standard(IEC61032) specifies details and dimensions of test probes intended to verify the protection provided by enclosures with regard to: – protection of persons against access to hazardous parts inside the enclosure; – protection of the equipment inside the enclosure against ingress of solid foreign objects. SMT 1214_AL 1.2 The object of thi...

Read More
Test Apparatus for Pressure Test At High Temperatures with BS 1363 Figure 10
10 May, 2024 284 Author: Cherry Shen

Test Apparatus for Pressure Test At High Temperatures with BS 1363 Figure 10

A set of three sample pins shall be tested by means of the apparatus shown in Figure 10 which has a blade 0.70+005mm wide and a radius of 3 mm ±0.1 mm. The test shall be made on one pin of each plug not used for the test described in 13.17.3. A sample shall be positioned as shown in Eigure 10 and the test apparatus shall be loaded so that the blade exerts a force of 2.5N on the sample. The test a...

Read More
Test Probe 13 with Cable with standard EN 61032
09 May, 2024 291 Author: Cherry Shen

Test Probe 13 with Cable with standard EN 61032

1. General 1.1 Scope and object This International Standard specifies details and dimensions of test probes intended to verify the protection provided by enclosures with regard to: – protection of persons against access to hazardous parts inside the enclosure; – protection of the equipment inside the enclosure against ingress of solid foreign objects. The object of this International S...

Read More
Test Pin UL 60950-1 Figure2B S2962D
08 May, 2024 282 Author: Cherry Shen

Test Pin UL 60950-1 Figure2B S2962D

1 General 1.1 Scope 1.1.1 Equipment covered by this standard This standard is applicable to mains-powered or battery-powered information technology equipment, including electrical business equipment and associated equipment, with a RATED VOLTAGE not exceeding 600 V and designed to be installed in accordance with the Canadian Electrical Code.Part1.CSA C22.1 12:General Requirements-Canadian Electric...

Read More
Withdrawal Pull Gauges for Effectiveness of Contact of BS1363-2 Figure 16
07 May, 2024 282 Author: Cherry Shen

Withdrawal Pull Gauges for Effectiveness of Contact of BS1363-2 Figure 16

6 General conditions for type testing 6.1 All tests shall be type tests. Unless otherwise specified in this part of BS 1363 the socket-outlets shall be tested as delivered by the manufacturer or responsible vendor and under normal conditions of use, at an ambient temperature of 20 ℃ ±5 °C, after being conditioned at normal laboratory temperature and humidity levels for at least 4 days. GNGPL 3...

Read More
Receptacle Test Fixture of UL 498 Figure 124.1
06 May, 2024 343 Author: Cherry Shen

Receptacle Test Fixture of UL 498 Figure 124.1

Assembly Security Test A flush receptacle having a 5-15R,5-20R,6-15R, or 6-20R configuration is to be mounted in the fixture described in Figure 124.1, and 50 lbf (220 N) is to be applied, as shown in Figure 124.2, for a period of 10 s by means of a push-out tool inserted into the slots of the receptacle. The push-out tool required for configuration 5-15R is to be as shown in Figure 124.3. The too...

Read More
What should I do if the results measured by the colorimeter are abnormal
05 May, 2024 299 Author: Cherry Shen

What should I do if the results measured by the colorimeter are abnormal

Performance configuration of colorimeter: 1. “You need to know which colorimeter is suitable for your industry, and the requirements for color difference accuracy are different for each industry, that is, △ Eab. If △ Eab is between 0-1, you must choose an instrument with higher accuracy;”; These are generally rubber and plastic, paint and paint industries; If you do not need a rela...

Read More
Brief introduction of ipx9k High Temperature Pressure Jet Waterproof Test Chamber
04 May, 2024 302 Author: Cherry Shen

Brief introduction of ipx9k High Temperature Pressure Jet Waterproof Test Chamber

The ipx9k High Temperature Pressure Jet Waterproof Test Chamber is characterized by a waterproof grade of 9, indicating high temperature and high pressure water spraying, and spraying high temperature and high pressure water in various directions of the shell for water spraying test. In addition, k represents a function of pressurization, and under such strict conditions, its water pressure will b...