EU Legislation has established a mandatory standard known as RoHS. It stands for “Restriction of Hazardous Substances” (Restriction of Hazardous Substances). We have formally implemented this standard since July 1, 2006. It is mainly used to regulate the materials and process the means of electrical and other electronic products.
This standard aims to remove the six items as follows:
• lead
• mercury
• hexavalent chromium
• polybrominated biphenyls and polybrominated diphenyl ethers in electrical and electronic products.
• It stipulates that the content of lead should not exceed 0.1%.
Accessories
Computer-related accessories are present; the printer is also included in the package. Other accessories include a wiring board, USB extension cable, wireless network, standard sample fixture, film, a slice of gold, etc. The required software is pre-installed on the computer.
• Assemble the computer.
• Connect the USB cable on the back of the equipment to the computer.
• If the length is not up to your demands, you can also use the USB extension cable.
• Connect the power cords to the 220 V 50 HZ power supply.
• Turn on the equipment and computer.
• Open the cover of the RoHS test equipment.
• A safety sensor switch is also present.
• If the cover is not closed, the equipment will not run.
• ‘’Warm-up’’ should be run once after you turn on the equipment.
• Put the gold in the equipment test position.
• Pay attention to the direction of the gold. The side with the words faces up, and the side with gold faces down.
• Close the equipment cover. Double click to open the software.
• The accurate time display of the test position camera will be shown on the screen. If you can not see the sample, right-click in the area shown on the left. Click ‘’open’’ to refresh the camera.
• The sample must be kept in the center of the camera area. Click ‘’warm-up’’. The warm-up time is a maximum of 1000 seconds.
• There is a countdown timer present at the bottom of the software. After warming up, you can also see the spectrum of the gold by clicking on ‘’Spectrum’’.
• The RoHS test equipment can always be on, and no need to turn it off. If the equipment is turned off, you have to warm up again after the next power is on.
• The gold is still placed on the test position of the equipment.
• Click ‘’Open Application’’. Choose any of the applications and click ‘’open’’.
• Click ‘’initialize’’ to initialize the equipment. When this prompt window appears, click on ‘’Confirm’’. The instrument is in the initialization process.
• After the initialization process is successful, a prompt window will appear. Click on ‘’confirm’’.
• Then the gold can be taken out and stored correctly. Most importantly, the warm-up and initialization, the gold needs to be placed on the test position of the equipment.
• If the equipment needs to be used every day, it needs to be initialized once a day.
• Now, take out the green standard sample package. You only need to take out the box from the valve bag.
• Do not open the package.
• In case you open the package, it will be invalid. And it would be best if you had a new standard sample package. Put the standard sample package on the test position of the equipment.
• Now, close the cover. Confirm that the green standard sample package is at the center of the camera area on the software.
• Click ‘’Open Application’’, select the ‘’Plastic’’ application and open it. Then, click on ‘’Start’. Enter the sample name and click on ‘’CONFIRM’’ in order to start testing the standard sample.
• During the test, click ‘’Qualitative’’ and ‘’Auto analysis’’ in order to automatically analyze the elements and content of the sample.
• You can manually add the other elements you want to analyze.
• After the test, right-click on the spectrum area to view all the spectrums. Switch to the test result table to view the content of each element.
• Compare the table’s data with the data of the standard sample provided by LISUN.
• The error within the range proves that the equipment is in average condition.
• It is necessary to test the standard sample package after each initialization. The process of testing the other samples is precisely the same.
• Put the sample into the test position of the equipment.
• Select the corresponding application and start the test. If the sample is particles or liquid, use the sample cup and test the film.
• Package the sample the same way as the green standard sample package. If the model is too big and the equipment cover can not be closed.
• You can put a coin on the sensor switch. The test can generally be performed without closing the cover.
• Click ‘’RECORD’’ to find the test result you want to review. You can preview or print the test report.
• Range of Analysis: 1ppm to 100 %
• Rate of Accuracy: RSD≤05% Au≥90%
• Test the physical state of the sample solid, powder, liquid
• Voltage of the light tube: 5KV ~ 50KV/ Optional imported light tube
• High voltage power supply: 0 ~ 50 KV; Light tube flow: 0μA ~ 1,000μA
• Camera: HD camera
• Collimator\filter automatic switching system
• Detector: Si-Pin/SDD (You can choose one)
• Resolution: Si-pin160±5eV/SDD135±5eV
• Multichannel analyzer; Testing time: 30 sec ~ 100sec
• ROHS analysis of some common elements: Cl, S, Pb, Hg, Br, Cr, Cd, Ba, Sb, As, etc.
• Qualitative and quantitative analysis software provides a support to Win7, Win8 and Win10, Win11
• High resolution and high definition camera for easy operations
• Camera and cabin lighting system
• Reliable power supply overcurrent
• Short-circuit protection to ensure RoHS test equipment safety.
• Automatic control test system,
• Convenient for customers to use.
We perform the RoHS test by following steps:
RoHS is a directive in the European Union. It stands for the Restriction of Hazardous Substances. It was created to control the use of hazardous materials found in electrical and electronic equipment and other goods.
Lisun Instruments Limited was found by LISUN GROUP in 2003. LISUN quality system has been strictly certified by ISO9001:2015. As a CIE Membership, LISUN products are designed based on CIE, IEC and other international or national standards. All products passed CE certificate and authenticated by the third party lab.
Our main products are Goniophotometer, Integrating Sphere, Spectroradiometer, Surge Generator, ESD Simulator Guns, EMI Receiver, EMC Test Equipment, Electrical Safety Tester, Environmental Chamber, Temperature Chamber, Climate Chamber, Thermal Chamber, Salt Spray Test, Dust Test Chamber, Waterproof Test, RoHS Test (EDXRF), Glow Wire Test and Needle Flame Test.
Please feel free to contact us if you need any support.
Tech Dep: Service@Lisungroup.com, Cell/WhatsApp:+8615317907381
Sales Dep: Sales@Lisungroup.com, Cell/WhatsApp:+8618117273997
Your email address will not be published. Required fields are marked *
[wpforms id="9600"]