IEC 60669-1:2017 applies to manually operated general purpose functional switches, for alternating current (AC) only with a rated voltage not exceeding 440 V with a rated current not exceeding 63 A, intended for household and similar fixed electrical installations, either indoors or outdoors. For switches provided with screwless terminals, the rated current is limited to 16 A. This fourth edition cancels and replaces the third edition published in 1998, Amendment 1:1999 and Amendment 2:2006.
LISUN supplies the fully test solutions for the following IEC 60669-1:2017, please see the below excel table:
IEC 60669-1:2017 Clause and Subject | LISUN Model |
Clause 10 Protection against electric shock | SMT-1175 |
Clause 12.2.5 Figure 10 information for deflection test | WDT-1 |
Clause 15.1 Resistance to ageing | GDJS-225A |
Clause 16.1 Insulation resistance and electric strength | WB2681A |
Clause 16.2 Test for measuring the insulation resistance | WB2673C |
Clause 18 Making and breaking capacity | CZKS-6 & DFX-30 |
Clause 19.1 Test for switches intended for inductive loads | DFX-WD20A |
Clause 19.3 Test for switches intended for self ballasted lamp loads | SBLL-3P20A |
Clause 20.2 Pendulum hammer test Table 21 | IK01-06P |
Clause 21 Resistance to heat | ZBP-T & GW-225 |
Clause 23 Creepage distances, clearances and distances through sealing compound | CK-1 |
Clause 24.1 Resistance to abnormal heat and to fire | ZRS-3H |
Clause 24.2 Resistance to tracking | TTC-1 |
Clause 25 Resistance to rusting | YWX/Q-010 |