Product No: SMT-12580
Test Finger Probe with 125mm * 80mm Circular Stop Face
The test probe is carried out with a test probes similar to that of test probe B of IEC61032 but having a circular stop face with a diameter of 125mm and thickness of 80mm instead of the non-circular face, the distance between the tip of the test finger and the stop face being 100 mm.
OSM/HA 467A
Standard EN 60335-2-14: 06+ amdts
Subject: Application of test probe for blenders
Question:
Which test probe is correct to check the protection for moving parts according to sub-clause 20.2 for belnders?
The clarification of the length of the stop face is necessary, due to its influences of the test result.
Decision:
The test probe is identical to figure 1 of DSH 416 , where the diameter of 50 mm will become 125 mm , the length of the stop face will be 80mm(180-100 mm).
Comment:
The decision was taken based on the OSM HA 467 in 2011 and confirmed by IEC/TC61Portoroz meeting in 2013.