Product No: SMT-TF03
The IEC 60335-2-29 Figure 103 Test Foot Probe is a specialized safety tool designed exclusively for household electrical appliances—such as washing machines, refrigerators, and electric ovens. It simulates accidental foot contact with appliance bases, lower gaps, or support structures to test two critical safety aspects: protection against electric shock (by detecting access to hazardous live parts) and structural integrity (ensuring enclosures don’t deform or expose internal components under foot pressure). Crafted with a conductive stainless steel foot-shaped tip (matching IEC 60335’s precise dimensions) and an insulated handle, it applies controlled force for consistent, standard-aligned testing. Durable and reliable, it’s essential for manufacturers to meet global household appliance safety regulations.
Specifications:
Tool Type: IEC 60335-2-29 Figure 103 Test Foot Probe (for household appliance foot-contact safety testing)
Probe (Foot Tip) Material: Stainless steel (highly conductive, resistance ≤ 0.1Ω; corrosion-resistant; precision-shaped to IEC 60335’s foot profile)
Core Function: Tests household appliances for electric shock risks and structural stability under accidental foot contact; verifies compliance with IEC 60335 safety requirements
Test Procedures:
1. Inspect the probe for damage (bent foot tip, cracked insulation, poor conductivity) and connect the tip to a live-part detection instrument.
2. Place the household appliance on a flat, stable surface; power it on and set it to normal operating mode.
3. Hold the insulated handle and position the foot tip over target areas (appliance base gaps, support around the feet,lower vent slots).
4. Apply a steady 150N force to the foot tip, maintaining pressure for 10 seconds (per standard guidelines).
5. Check for two outcomes: (1) detection instrument signals (indicating contact with live parts); (2) visible enclosure deformation.
6. Record results: pass if no live-part contact or deformation; fail if either issue occurs.

IEC 60335 Standard Test Foot Probe
© Copyright 2003 | Blog | Privacy
surge generator | emc test system | emi receiver | electrical safety tester | temperature chamber | salt spray test | environmental chamber | Sitemap

To provide the best experiences, we and our partners use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us and our partners to process personal data such as browsing behavior or unique IDs on this site and show (non-) personalized ads. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Click below to consent to the above or make granular choices. Your choices will be applied to this site only. You can change your settings at any time, including withdrawing your consent, by using the toggles on the Cookie Policy, or by clicking on the manage consent button at the bottom of the screen.

中文简体