Product No: SMT-F76
IEC 60335-2-16 Flat End Test Rod is designed and manufactured according to the IEC60335-2-16 clause 22.102. It is used to test concealment of the reset button of a protective device.Appliance is checked by applying a rod in any direction to touch the protective device which is in off state. The diameter of rod is 76 mm ±0.1mm and it has a flat end. There shall be a distance of at least 1.5mm between the rod and the button. The protective device shall not be operated with the rod and not automatically reset. Key features include a rigid test rod with a flat end, boasting a precise diameter of 76 mm ±0.1 mm. During testing, the rod is applied in any direction to contact the protective device (in the off state), with a mandatory minimum distance of 1.5 mm maintained between the rod and the reset button.
Specifications:
• Rod Diameter: 76 mm ± 0.1 mm
• Rod End Design: Flat end (for consistent contact during testing)
• Minimum Distance Requirement: At least 1.5 mm between rod and protective device button during test
• Core Function: Prevents accidental operation/auto-reset of protective devices during concealment checks
• Test Direction: Usable in any direction to simulate real-world contact scenarios
Test Procedures:
• Ensure the appliance’s protective device is in the off state.
• Hold the test rod and apply it to the protective device from any direction.
• Maintain a minimum 1.5mm gap between the rod and the reset button.
• Check if the protective device is operated or automatically resets.
• Record whether the test meets compliance requirements.
Applications:
• Concealment testing of reset buttons on household food waste disposers (per IEC 60335-2-16 Clause 22.102).
• Safety verification of protective device buttons on commercial food waste processing equipment.
• Compliance checks for similar kitchen appliances with hidden protective reset buttons.
• Quality control testing of food waste disposers during manufacturing.
Tags:IEC 60335 , SMT-F76
© Copyright 2003 | Blog | Privacy
surge generator | emc test system | emi receiver | electrical safety tester | temperature chamber | salt spray test | environmental chamber | Sitemap

To provide the best experiences, we and our partners use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us and our partners to process personal data such as browsing behavior or unique IDs on this site and show (non-) personalized ads. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Click below to consent to the above or make granular choices. Your choices will be applied to this site only. You can change your settings at any time, including withdrawing your consent, by using the toggles on the Cookie Policy, or by clicking on the manage consent button at the bottom of the screen.