Product No: LS-GWC-1
The LS-GWC-1 Heat Resistance Test Device for Cables is used for testing the heat resistance of non-metallic and composite catheters. During testing, the catheter sample is cut to a specified length and placed in a high-temperature environment with the device for a specified period of time under constant temperature, simulating the use of the catheter under high-temperature conditions. After heating, a load perpendicular to the axis is applied to the sample through a steel rod and weights within the device and maintained for a specified time, allowing the sample to cool to room temperature under the load. After cooling, the load is removed, and a gauge is immediately passed through the vertically aligned sample under its own weight. Whether the gauge passes through smoothly determines whether the catheter’s heat resistance meets the standards, providing a standardized testing procedure for verifying the compliance of catheter heat resistance performance.
Standard:
| Standards | Standards Name |
| IEC 61386-1:2020 | Conduit systems for cable management – Part 1: General requirements |
| GB/T 20041.1-2015 | 电缆管理用导管系统 第 1 部分:通用要求 |
| GB/T 14823.2-1993 | 电气安装用导管 特殊要求 刚性绝缘材料平导管 |
| JG 3050 | 建筑用绝缘电工套管及配件 |
| ZBG 33008 | 聚氯乙烯塑料波纹电线管 |
Specification:
• Steel rod diameter: 6mm
• Steel rod weight: 500g
• Impact Weight: 0.5KG, 0.5KG, 1.0KG, 2.0KG, 4.0KG and 8.0KG
• According to the standard requirements, the 400℃ high temperature test chamber GW-225-400 must be selected as a supporting accessory.
Operation Instruction:
• Cut the required catheter into samples with a length of 100 ± 5mm. Place the samples along with this instrument in an oven for 4 hours ± 5 minutes, with the temperature inside the oven based on Table 2 of IEC 61386-1:1996 (GB 20041.1-2005 )”onduit systems for electrical installations- Part 1:General requirements”, with an error of ± 2°C.
• After the heating stage is completed, lift the steel rod, place it on the specimen, and apply the corresponding weights to exert force for 24 hours ± 15 minutes, ensuring that the load is perpendicular to the axis of the conduit.
• The total load applied to the specimen, including the steel rod, should comply with the standard, and the load should be applied to the middle part of the specimen. The specimen should then be allowed to cool to room temperature under the applied load.
• Then remove the load and immediately allow the relevant gauge to pass through the specimen, which is in a vertical position, without any initial velocity and under its own weight, through the conduit.

Table 2- Upper Temperature range

Figure 8 Test apparatus for resistance to test
Tags:LS-GWC-1
© Copyright 2003 | Blog | Privacy
surge generator | emc test system | emi receiver | electrical safety tester | temperature chamber | salt spray test | environmental chamber | Sitemap

To provide the best experiences, we and our partners use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us and our partners to process personal data such as browsing behavior or unique IDs on this site and show (non-) personalized ads. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Click below to consent to the above or make granular choices. Your choices will be applied to this site only. You can change your settings at any time, including withdrawing your consent, by using the toggles on the Cookie Policy, or by clicking on the manage consent button at the bottom of the screen.