IEC 60320-1:2021 clause 16 Figure 3 and Table 15 Coupler Pull-out Force Test Device

Product No: LS-B46

Leave a Message

[wpforms id="9600"]
  • Description
  • LS-B46 Coupler Pull-out Force Test Device is designed and manufactured in full accordance with standard IEC 60320-1:2021 Clause 16 Figure 3 and Table 15, and is suitable for checking the maximum extraction force of the appliance coupling. The minimum extraction force is achieved by inserting a single-stage plug in a handheld manner. The LS-B46 consists of a control cabinet, mounting plate, heating device, standard socket gauge, weight hook, main weights and additional weights. 

    Test principle: Fix the appliance input socket to the bottom plate of the heating device so that the pin of the appliance input socket is vertical and the free end of the plug is facing downward. Select the corresponding weight for the corresponding sample, insert the connector sample into the appliance input socket, and hang the corresponding weight at the end of the connector wire. The connector should not shake when the main weight is suspended, and the supplementary weight is allowed to fall on the main weight from a height of 5cm. The connector should not remain in the appliance input socket. For testing connectors under hot and extremely hot conditions, the heating function should be turned on, and the maximum extraction force test should be started after the temperature is reached.

    Specifications:

    Station Single station
    Operation Method Manual
    Heating Method Ambient temperature to 180°C, presettable
    Standard Gauge Standard gauges include 10A heat-resistant, 10A extreme heat-resistant, and 16A extreme heat-resistant for heating measurements

    Standard Maximum Extraction Force Weight
    (Refer to IEC 60320-1:2021 Table 5)

    50N (main weight 45N with hook, additional weight 5N)
    60N (main weight 45N with hook, 4N and 6N, additional weight 6N)
    Note: The weight hook is included in the weight of the 45N weight

    Standard Minimum Extraction Force Weight
    (Refer to IEC 60320-1:2021 Table 5)
    1.5N weight and 10A live or ground single-pole plug
    2N weight and 16A live or ground single-pole plug
    Note: The weight of the single-pole plug is included in the weight of the corresponding weight
    Working Power and Environment Power supply: AC220V±10%/50-60Hz, working temperature 5-35℃, humidity 30%-90%
     

    IEC 60320-1:2021 Table 5

    IEC 60320-1:2021 Figure 3