Product No: PRC-6M
The PRC-6M Precision Photometric Calibration System is suitable for the inspection, measurement and calibration of illuminometers, illuminance probes and luminous intensity within the visible light range of 380~780nm. It is an essential piece of equipment for photometry laboratories and photometric measurement institutions. This system meets the requirements of standards such as “JJG 245 Verification Regulation of Illuminometers “and “JJG 246 Verification Regulation of Luminous Intensity Standard Lamps”.
System Configuration:
| No. | Optical guide Confirguration | Quantity | Unit | Specifications |
| 1 | Optical guide | 1 | Set | 6 meters in length, the base is made of 6060 standard aluminum profile |
| 2 | Baffle | 4 | Piece | Opening diameter Φ18cm, V-shaped block base, easy to put in and take out |
| 3 | Light intensity lamp adjustment device | 1 | Set | Light intensity lamp lifting and universal adjustment |
| 4 | illuminometers rotating device | 1 | Set | Coaxial position switching device for standard illuminometers and measured illuminometer |
| 5 | Light intensity standard lamp | 1 | Piece | LISL-400: 2856K, approximately 500cd, with NIM calibration certificate |
| 6 | Standard illuminometers | 1 | Set | 0.1lx~200,000lx: NIM calibration certificate |
| 7 | DC power supply | 1 | Set | Accuracy:1mV/0.1mA |
Notes:
• The system configurations of PRC-2M and PRC-4M are consistent with that of PRC-6M, with the only difference being that the lengths of their optical guide are 2 meters and 4 meters respectively.
• Darkroom size requirements: 3m (W) *optical guide length + 2m (L) for placing optical guide , calibration instruments and accessories; all walls, ceilings and floors in the room are painted matte black, and the ambient temperature is controlled to meet the standard value.
© Copyright 2003 | Blog | Privacy
surge generator | emc test system | emi receiver | electrical safety tester | temperature chamber | salt spray test | environmental chamber | Sitemap

To provide the best experiences, we and our partners use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us and our partners to process personal data such as browsing behavior or unique IDs on this site and show (non-) personalized ads. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Click below to consent to the above or make granular choices. Your choices will be applied to this site only. You can change your settings at any time, including withdrawing your consent, by using the toggles on the Cookie Policy, or by clicking on the manage consent button at the bottom of the screen.