  • Description
  • During the tests using these gauges, shutters shall be held open.

    The metallic parts of gauges A, B and C are made of hard corrosion-resistant metal (e.g. stainless steel).

    An electrical indicator with a voltage not less than 40V and not more than 50 V is used to show contact.

    The gauge A shall be introduced through the entry holes of the socket-contactassembly in every possible position until the plane XX is fully in contact with the engagement face.

    The indicator shall not light.

    The pins of gauges B and C shall be completely inserted. Then,
    – for gauge B the indicator shall light;
    – for gauge C the indicator shall not light.

    IEC 60906-1 Figure 2