LM-79 Moving Detector Goniophotometer (Mirror Type C)
LSG-6000
High Precision Rotation Luminaire Goniophotometer
LSG-1890B
High Precision Rotation Luminaire Goniospectroradiometer
LSG-1890BCCD
Goniophotometer for Automotive and Signal Lamps
LSG-1950
Goniophotometer for Traffic Signal Lamps
LSG-1950S
Compact Goniophotometer
LSG-1200A
Near Field Moving Detector Goniophotometer
LSG-1900B
Select an organization
to browse standards
Product No: TPB-UL935
The TPB-UL935 Thermally Protected Ballast Heating Test Chamber is a high-temperature environment simulation device designed by LISUN specifically for electronic and electrical components such as lamp ballasts. The function is to accurately replicate natural high-temperature scenarios, verifying the thermal protection performance and high-temperature adaptability of ballasts and other components through a stable, controllable temperature environment. The equipment utilizes high-grade stainless steel inner and outer chambers and ultra-fine glass wool insulation, along with multiple dedicated strip heaters, enabling wide temperature control from room temperature + 10°C to 100°C.
The TPB-UL935 Thermally Protected Ballast Heating Test Chamber also features three switchable temperature measurement points for real-time monitoring of temperature changes at different locations during testing. It is widely used for pre-shipment thermal protection verification of ballasts, high-temperature performance optimization during the R&D phase, and high-temperature environmental testing for compliance certification. It effectively ensures the safe operation of ballasts in high-temperature conditions and avoids safety risks such as fires caused by thermal protection failure.
Standards:
| Standards No. | Standards Name |
| IEC 61347-1:2024 | Lamp controlgear – Part 1: General and safety requirements |
| UL 935:2007 | Standard for Fluorescent Lamp Ballasts (with Class P Thermal Protection) |
| GB 19510.1-2023 | 灯的控制装置 第 1 部分:一般要求和安全要求 |
Specifications:
| Parameters | Specifications |
| Internal size (L*W*H) | 610mm*610mm*610mm (suitable for most specifications of ballasts, meeting batch or single sample testing needs) |
| Temperature range | RT+10℃~+100℃ (RT is room temperature, covering the typical temperature range of ballast high temperature adaptability test) |
| Temperature uniformity | ≤±2℃ |
| Temperature fluctuation | ≤±0.5℃ |
| Inner and outer box material | High-grade stainless steel plate (corrosion-resistant and high-temperature-resistant, to prevent aging or rust of the box from affecting the test accuracy) |
| Insulation material | Ultra-fine glass wool insulation material (excellent thermal insulation performance, reduces heat exchange between inside and outside the box, and reduces energy consumption) |
| Sample rack configuration | Special wooden test sample rack (good insulation, avoids heat conduction interference from metal racks, and is suitable for placing ballasts of different sizes) |
| Heater type | Special strip heater (size 300mm*40mm, power 300W per group) |
| Number of heaters and connection method | There are 4 groups in total, with power supply connected in parallel (the temperature rises quickly, a single group failure does not affect the overall test, improving equipment reliability) |
| Temperature measurement point | Three temperature measurement points (can be switched at any time to meet the temperature monitoring needs of different locations, such as sample surface and box environment) |
| Temperature control method | Intelligent PID temperature control system (automatically adjusts heating power, accurately maintains set temperature, and supports temperature curve recording) |
| Safety protection | Over-temperature protection (automatically cuts off heating power when the temperature exceeds the set upper limit), overload protection (avoids safety problems caused by heater failure) |
| Observation and operation | Equipped with high temperature resistant glass observation window (for real-time observation of sample status) and touch operation panel (for convenient temperature setting and data reading) |
| Power supply | AC 230V±10%, 50/60Hz, total power ≤1200W |

© Copyright 2003 | Blog | Privacy
surge generator | emc test system | emi receiver | electrical safety tester | temperature chamber | salt spray test | environmental chamber | Sitemap

To provide the best experiences, we and our partners use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us and our partners to process personal data such as browsing behavior or unique IDs on this site and show (non-) personalized ads. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Click below to consent to the above or make granular choices. Your choices will be applied to this site only. You can change your settings at any time, including withdrawing your consent, by using the toggles on the Cookie Policy, or by clicking on the manage consent button at the bottom of the screen.