LM-82 Test Method

LM-82 is a standard for the reliability testing of LED test instruments released by the American Lighting Engineering Society (IES). This standard specifies a series of test methods to help evaluate the performance and reliability of LED lighting products.

LM-82 standard

LM-82 Standard Overview
The LM-82 is a standard for testing the reliability of LED lighting products. It aims to provide a standardized method to help manufacturers and consumers evaluate and compare the life and performance of different LED lighting products. This standard contains a series of testing methods, focusing on the life evaluation and thermal analysis of LED light sources.

Test Methods
1. Life test
Life test is the core part of the LM-82 standard. This test runs LED lighting products for a long time, and tests its initial light output and color stability under different temperature conditions under different time interval. The purpose of testing is to evaluate the life of LED lighting products and predict its performance in practical applications.

LM-82 Test Method

2. Hot analysis
Hot analysis is another important test method in the LM-82 standard. LED lighting products will generate a lot of heat during the work process. If it cannot be effectively dissipated, it will seriously affect its life and performance. Through different thermal tests, the heat dissipation performance of LED lighting products can be evaluated and the appropriate heat dissipation design can be determined.

3. Light output and led color tester
The LM-82 standard requires testing the light output and color stability of LED lighting products under different temperature conditions. These tests can help evaluate the performance and stability of the product in different temperature environments. In the test, the optical output and color differences are measured by equipment such as optical meter and chromatinometer.

4. Electrical feature test
Electrical characteristics test is another important content in the LM-82 standard. These tests include measurement of electrical parameters such as current, voltage, and power factor. Through electrical characteristics, you can evaluate the electrical performance of LED lighting products and determine whether it meets relevant international standards and security requirements.

5. Variable temperature test
The variable temperature test is a test to simulate the actual use environment under different temperature conditions. By performing long -term continuous testing within a specific temperature range, the performance and reliability of the product can be evaluated under different temperature conditions.

LM-82 is a standard for the reliability testing of LED lighting products, which contains a number of test methods, covering LED light source life evaluation, thermal analysis, light output and color stability test, electrical characteristics test, and variable temperature Test and other content. These test methods can help manufacturers and consumers evaluate the performance and reliability of LED lighting products, and make reasonable choices and comparisons. By complying with the LM-82 standard, the quality and reliability of LED lighting products can be ensured to promote the development of the LED lighting industry.

video
LISUN released IES LM-82-12 technical standards for the North American Lighting Engineering Association. The test solution provided by LISUN is LPCE-2 High Precision Spectroradiometer with Constant temperature Integrating Sphere System. It includes LMS-9000C spectroradiometerconstant temperature integrating sphere systemDC Power supplyAC power supplydigital power meter and so on. It also should work with Multiplex Temperature Tester. Completely meet the test requirements of LM-82-12 and get test report. LISUN constant temperature integrating sphere system according to the requirement of IEC standards, the standard test temperature is 25℃. But high power lamps such as HID lamps and LED outdoor luminaires will produce a lot of heat during the test, thus the temperature inside the integrating sphere can not meet the requirement of IEC standards. LISUN designed the Constant Temperature Integrating Sphere (thermostatic sphere or temperature controlled integrating sphere) which keeps the temperature inside of the sphere stable at 25℃.
High Precision Spectroradiometer Integrating Sphere System LPCE 2(LMS 9000) AL2

High Precision Spectroradiometer Integrating Sphere System LPCE 2(LMS 9000) 

Lisun Instruments Limited was found by LISUN GROUP in 2003. LISUN quality system has been strictly certified by ISO9001:2015. As a CIE Membership, LISUN products are designed based on CIE, IEC and other international or national standards. All products passed CE certificate and authenticated by the third party lab.

Our main products are GoniophotometerIntegrating SphereSpectroradiometerSurge GeneratorESD Simulator GunsEMI ReceiverEMC Test EquipmentElectrical Safety TesterEnvironmental ChamberTemperature ChamberClimate ChamberThermal ChamberSalt Spray TestDust Test ChamberWaterproof TestRoHS Test (EDXRF)Glow Wire Test and Needle Flame Test.

Please feel free to contact us if you need any support.
Tech Dep: Service@Lisungroup.com, Cell/WhatsApp:+8615317907381
Sales Dep: Sales@Lisungroup.com, Cell/WhatsApp:+8618117273997

Tags: ,

Leave a Message

Your email address will not be published. Required fields are marked *

[wpforms id="9600"]