IS 16107-2-1: 2012 Luminaires Performance-Part 2 Particular Requirements-Section 1 LED Luminaire

FOREWORD

This Indian Standard IS 16107 (Part 2/Sec1) was adopted by the Bureau of Indian Standards, after the draft finalized by the Illumination Engineering and Luminaires Sectional Committee had been approved by the Electrotechnical Division Council.

This standard IS 16107 (Part 2/Sec1) specifies the performance requirements for LED luminaires for general lighting applications. The other part in the series is:
Part 1 General requirements

Safety requirements have been covered in IS 10322 (Part 1): 2012‘Luminaires:Part 1 General requirements and tests (first revision)’.

This standard for LED luminaires for general lighting applications acknowledges the need for relevant tests for luminaires using this new source of electrical light, sometimes called solid state lighting. This standard is seen in close context with simultaneously developed publication of performance standards for luminaires in general and for LED modules. Changes in the LED luminaires standard will have impact on the module standards and vice versa, due to the behaviour of LED.

The provisions in the standard represent the technical knowledge of experts from the fields of the semiconductor (LED chip) industry and of those of the traditional electrical light sources and luminaires.

This standard is based onIEC/PAS62722-2-1(2011)‘Luminaire performance –Part 2-1: Particular requirements for LED luminaire’ issued by the International Electrotechnical Commission (IEC) with following modifications:
Schedule of type test and acceptance test has been incorporated.

IS 16107-2-1:2012 Luminaires Performance-Part 2 Particular Requirements-Section 1 LED Luminaire

For the purpose of deciding whether a particular requirement of this standard is complied with, the final value, observed or calculated expressing the result of a test or analysis, shall be rounded off in accordance with IS2: 1960 ‘Rules for rounding off numerical values (revised)’. The number of significant places retained in the rounded off value should be the same as that of the specified value in this standard.

LISUN supplies the fully test solutions for the following IS 16107-2-1: 2012, please see the below excel table:

IS 16107-2-1: 2012 Clause and Subject LISUN Model
Clause 1.1 Life time of LED luminaires LEDLM-84PL
Clause 6.2 rated LED module lifetime
Clause 10 LED LUMINAIRE LIFE
Clause 4.1 Table 1  LEDLM-84PL & LPCE-2(LMS-9000)
Clause 8.1 Luminous Flux LPCE-2(LMS-9000)
Clause 8.2 Luminous Intensity Distribution, Peak Intensity and Beam Angle LSG-1890B
Clause 9 Chromaticity Coordinates,CCT and CRI LMS-6000