IEC 60884-1 IEC 60669-1 Clause 12.3.11 Electrical and Thermal Stresses Test Device

Product No: JCY-1

Leave a Message

[wpforms id="9600"]
  • Description
  • Video
  • The JCY-1 Screwless Terminals withstand the electrical and Thermal stresses Test Device fully comply with Clause 12.3.11 of IEC 60884-1 (GB/T 2099.1) and IEC 60669-1 (GB/T 16915.1). During operation, the test current is connected according to the standard. After a certain period, the voltage drop is measured (judgment criterion: the voltage drop is not greater than 22.5mV) to inspect whether the non-threaded terminals can withstand the electrical and thermal stresses that occur during normal use.

    Specification:
    • Voltage meter range: 0~50mV (3%±1A)
    • Current meter range: 0~30A (3%±1mV)
    • Supply voltage: 4~12V
    • Supply current: 0~30A
    • Test cycle setting: 0~9,999 times

    Note: The JCY-1 Screwless Terminals withstand the electrical and Thermal stresses Test Device is typically used in conjunction with the JCY-2 Screwless Terminals Bending Test Device .