This regulation applies to the approval of headlamps equipped with halogen lamps (HS2 lamps), which are provided for the equipment of mopeds and vehicles treated as such.
For measurements, the measuring screen shall be located at a distance of 25/m in front of the headlamp and perpendicular to the line joining the filament of the lamp and the point HV; the line H-H shall be horizontal.
Laterally, the headlamp shall be so aimed that the centre of the beam is on the vertical line V-V.
Vertically, the headlamp shall be so aimed that the “cut-off” is situated 250/mm below the line H-H. It shall be as horizontal as possible.
The headlamp when aimed according to paragraphs 2 and 3 above, shall meet the following conditions:
Measuring point
Illumination E/Lux
Any point on and above the line H-H
0.7
Any point on the line 35L-35R except 35V
1
Point 35V
2
Any point on the line
25L-25R
2
Any point on the line 15L-15R
0.5
LISUN following instruments fully meet ECE R.82 UNIFORM PROVISIONS CONCERNING THE APPROVAL OF MOPED HEADLAMPS EQUIPPED WITHFILAMENT HALOGEN LAMPS (HS2 LAMPS)